Power stations

How long will EcoFlow DELTA 2 run a fridge?

An estimate for the 1,024 Wh station: a table for different fridges and a calculator with the numbers filled in.

Quick answer

≈ 17 hours for a typical fridge (0.8 kWh per day). An efficient new model runs up to ≈ 23 h, an older or large one ≈ 12 h.

The calculator is prefilled for DELTA 2 and a 33 W average fridge load. Change it to your own.

Capacity unit
Wh

From the battery label or power station specifications.

W

Average power used by your devices, not the maximum rating of your inverter.

Losses & available energy
%

90% is a starting assumption. Efficiency depends on the inverter and its load.

%

The fraction of nominal energy you plan to use. Allow for starting charge, reserve and battery limits.

W

Separate inverter losses. If already included in your efficiency figure, leave this at 0 W.

Estimated result

Battery runtime

—h

Available energy
—
Battery power draw
—

An estimate for your inputs. Actual performance depends on temperature, battery condition and changing loads.

Capacity alone does not establish compatibility. Check battery voltage, battery and BMS current limits, startup loads and inverter specifications.

DELTA 2 specs that matter for a fridge

SpecEcoFlow DELTA 2
Capacity1,024 Wh, LiFePO₄
AC output1,800 W, 2,700 W surge, pure sine wave
X-Boostup to 2,400 W (EU) / 2,200 W (US) for heating appliances
Switchover on outageEPS, under 30 ms
AC chargingup to 1,200 W, 0–80% in ≈ 50 min
Expansionto 2,048 Wh (DELTA 2 Extra Battery) or 3,040 Wh (DELTA Max EB)
Cycle life3,000 cycles to 80% capacity
Weight≈ 12 kg (27 lb)

How many hours will a fridge run?

A fridge cycles on and off, so we use average power over a day (kWh per day ÷ 24). For your own model, check the energy label: yearly kWh ÷ 365.

DELTA 2 estimate: 90% usable energy, 85% inverter efficiency, 15 W self-consumption.
ScenarioAverage loadRuntime
Efficient fridge, 0.5 kWh/day21 W≈ 23.3 h
Typical fridge, 0.8 kWh/day33 W≈ 17 h
Older or large fridge, 1.2 kWh/day50 W≈ 12.5 h
0.8 kWh/day fridge + 15 W router48 W≈ 12.8 h

How we calculated it

Runtime (h) = 1,024 Wh × 0.9 ÷ (load ÷ 0.85 + 15 W)

For a typical fridge using 0.8 kWh per day the average load is ≈ 33 W: 921.6 ÷ (33.3 ÷ 0.85 + 15) ≈ 17 hours.

The 15 W self-consumption is our assumption: EcoFlow does not publish an exact figure for DELTA 2. With small loads it noticeably cuts runtime, so check the real number in the EcoFlow app and enter it in the calculator.

Can it handle the compressor start-up?

A compressor briefly draws several times its running power on start-up. For a household fridge that is usually a few hundred watts, while DELTA 2 handles a 2,700 W surge, so starting a normal fridge is not an issue. Inverter fridges start even more gently.

How to make it last longer

  • Keep the door closed: a closed fridge stays cold for hours.
  • Turn the AC output off when the fridge does not need power (for example, for an hour or two overnight) to avoid inverter self-consumption.
  • Use EPS mode: keep the station plugged in and it switches to battery in under 30 ms when the grid drops — the fridge won’t notice.
  • For long outages add an Extra Battery — runtime roughly doubles.

Estimates only; actual runtime is not guaranteed. Always check your equipment specs and the manufacturer’s instructions.

Frequently asked questions

Can DELTA 2 run a fridge and a freezer at the same time?

Yes, power-wise there is plenty of headroom: together they rarely exceed 300–400 W even on start-up. Runtime drops though: add up their daily kWh and enter the average load in the calculator.

Can I keep DELTA 2 plugged in all the time?

Yes, that is how EPS mode works: devices run from the grid, and on an outage the station switches to battery in under 30 ms. For long-term storage the manufacturer recommends limiting the charge level in the app.

Why does the station show a different remaining time?

The station uses instantaneous load, and a fridge jumps from a few watts to around a hundred. Go by the average over several hours.

Sources and assumptions

Updated November 6, 2026

Related calculations