Batteries & backup power

Home backup, calculated.

Add your devices and choose how long you need backup power.

100% means running continuously. A refrigerator duty cycle of 35% is only an example; measured consumption is preferable.

h
V

Use the nominal voltage on your battery label. LiFePO₄ batteries commonly use 12.8 / 25.6 / 51.2 V.

Losses & available energy
%

90% is a starting assumption. Efficiency depends on the inverter and its load.

%

The fraction of nominal energy you plan to use. Allow for starting charge, reserve and battery limits.

W

Separate inverter losses. If already included in your efficiency figure, leave this at 0 W.

Estimated result

Required nominal capacity

—kWh

Average power use
—
Sum of device power ratings
—

An estimate for your inputs. Actual performance depends on temperature, battery condition and changing loads.

Capacity alone does not establish compatibility. Check battery voltage, battery and BMS current limits, startup loads and inverter specifications.

How we calculate

We calculate energy for the required runtime and include conversion losses. Nominal capacity must exceed energy used if some charge remains in reserve.

Capacity (Wh) = (load (W) ÷ efficiency + inverter idle power (W)) × time (h) ÷ usable fraction

Example: 200 W for 6 hours, 90% efficiency, 90% usable capacity and 10 W idle power. About 1548 Wh, or 1.55 kWh, of nominal capacity is required. At 51.2 V, this is about 30.2 Ah.

For each device, average power = running power × quantity × on-time fraction. We add the average powers and use the formula above. Startup currents are not calculated in this energy model.

Percentages in the formulas are decimal fractions: 90% = 0.9. Energy (Wh) = capacity (Ah) × nominal voltage (V).

Sources & assumptions

These formulas estimate energy. Efficiency, usable capacity and power consumption are user inputs, not specifications of a particular model.

Methodology updated October 6, 2026

Common questions

What should I enter for a refrigerator?

Use its running power and compressor duty cycle. The defaults of 150 W and 35% are examples, not universal specifications. Measuring energy use with a power meter in your conditions is preferable.

Does the sum of power ratings determine inverter size?

It is only the sum of the entered running power ratings. A refrigerator or pump can require much higher startup power. This calculator estimates energy, not a safe inverter model.

What does 50% on-time mean?

The device uses the entered power for half of the selected backup period. For 6 hours of backup, this means 3 hours running. Use 100% for a router that stays on continuously.

All calculators