Power stations

EcoFlow DELTA 2 vs BLUETTI AC180: which to choose

Specs side by side, runtime at the same load and a clear verdict for different needs.

Quick answer

AC180: more capacity and a faster UPS — better for a boiler or PC. DELTA 2: expandable to 3 kWh with Wi-Fi control — better for long outages.

Prefilled for DELTA 2 (1,024 Wh). For the AC180, enter 1,152 Wh.

Capacity unit
Wh

From the battery label or power station specifications.

W

Average power used by your devices, not the maximum rating of your inverter.

Losses & available energy
%

90% is a starting assumption. Efficiency depends on the inverter and its load.

%

The fraction of nominal energy you plan to use. Allow for starting charge, reserve and battery limits.

W

Separate inverter losses. If already included in your efficiency figure, leave this at 0 W.

Estimated result

Battery runtime

—h

Available energy
—
Battery power draw
—

An estimate for your inputs. Actual performance depends on temperature, battery condition and changing loads.

Capacity alone does not establish compatibility. Check battery voltage, battery and BMS current limits, startup loads and inverter specifications.

Spec comparison

SpecEcoFlow DELTA 2BLUETTI AC180
Capacity1,024 Wh1,152 Wh
ChemistryLiFePO₄LiFePO₄
Cycle life3,000 cycles to 80%3,500+ cycles to 80%
AC output1,800 W, 2,700 W surge1,800 W, 2,700 W surge
High-power modeX-Boost up to 2,400 W (EU) / 2,200 W (US)Power Lifting up to 2,700 W, heating only
Outage switchoverEPS, under 30 msUPS, 20 ms or less
AC chargingup to 1,200 W, 0–80% ≈ 50 minup to 1,440 W, 0–100% ≈ 1.3–1.8 h
Solar inputup to 500 Wup to 500 W
Capacity expansionyes, up to 3,040 Whno native expansion
AppWi-Fi + BluetoothBluetooth
Weight≈ 12 kg (27 lb)≈ 16 kg (35 lb)

Runtime at the same load

Same assumptions for both: 90% usable energy, 85% efficiency, 15 W self-consumption.
LoadDELTA 2AC180
50 W≈ 12.5 h≈ 14 h
100 W≈ 6.9 h≈ 7.8 h
200 W≈ 3.7 h≈ 4.1 h
500 W≈ 1.5 h≈ 1.7 h

The AC180 holds 128 Wh more, so all else equal it runs about 12% longer.

Which one to choose

BLUETTI AC180 — if you want a UPS for a boiler or computer: more capacity, faster switchover (≤ 20 ms) and faster AC charging.

EcoFlow DELTA 2 — if outages may get longer: capacity can grow to 3 kWh with an extra battery. Plus Wi-Fi control and 4 kg less weight.

Both now have successors — EcoFlow DELTA 3 with faster switchover and BLUETTI AC180P with more capacity. Compare current prices before buying; the previous generation is often the better deal.

Estimates only; actual runtime is not guaranteed. Always check your equipment specs and the manufacturer’s instructions.

Frequently asked questions

Which is better for a gas boiler?

Both handle a boiler power-wise. The AC180 runs a little longer and switches over faster (≤ 20 ms vs 30 ms).

Can I add an extra battery to the AC180?

The AC180 has no native capacity expansion like DELTA 2’s Extra Battery. If you plan to add capacity, look at DELTA 2 or larger BLUETTI models.

Can they boil a kettle?

Yes: both deliver 1,800 W, more in X-Boost or Power Lifting mode. But a 2 kW kettle eats a noticeable share of the charge in a few minutes.

Sources and assumptions

Updated November 6, 2026

Related calculations