The main problem is starting current
A submersible pump starts direct-on-line and briefly draws 4–6.5 times its running current (Grundfos states this range in its SP pump manual). The start lasts a fraction of a second, but the station’s inverter has to survive it.
| Pump power | Start-up peak | Station rated output |
|---|---|---|
| 370 W | 1,480–2,405 W | from 555 W |
| 550 W | 2,200–3,575 W | from 825 W |
| 750 W | 3,000–4,875 W | from 1,125 W |
| 1100 W | 4,400–7,150 W | from 1,650 W |
Most 1 kWh portable stations have a surge rating around 2,700 W. That covers small surface pumps and pumps up to ≈ 0.4–0.5 kW. A 0.75–1.1 kW well pump needs a station with a 5–7 kW surge, or a soft start.
How to reduce the starting current
- A soft starter or variable-speed drive cuts the peak several-fold. Have it installed by a professional.
- A bigger pressure tank — the pump starts less often.
- Don’t start other heavy loads at the same time as the pump.
How much energy the pump uses
A pump runs in short bursts. A 750 W pump running 30 minutes a day uses only ≈ 0.4 kWh. So for a pump the station’s surge rating matters more than its capacity.
Estimates only; actual runtime is not guaranteed. Always check your equipment specs and the manufacturer’s instructions.